Thorn System 1700 Fire Alarm Manual
Tyco (Thorn Security) Fire Alarm Controllers, Smoke / Heat Detectors, Manual Call Points. Ocean Automation Solutions are able to engineer, supply, install and.
It must be the same as the 1600 range. Let me know your email and I will try to send you a hard copy through the snail mail. Rich The 1700 is conventional, modular from 8 zone to 64 IIRC. I have never seen one with automatic reset, why would you want that on a Fire System?
From memory, the 1700 first started appearing in something like 1989 - very reliable and a pleasure to work with. HTIOSH RayB - Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (Version: 6.0.542 / Virus Database: 336 - Release Date. It must be the same as the 1600 range. Let me know your email and I will try to send you a hard copy through the snail mail. Rich The 1700 is conventional, modular from 8 zone to 64 IIRC.
I have never seen one with automatic reset, why would you want that on a Fire System? From memory, the 1700 first started appearing in something like 1989 - very reliable and a pleasure to work with. HTIOSH RayB hi ray, my legs are getting tired having to keep walking back to the panel to reset them when i'm testing them,always thought that they couldn't walk test but walked into an office the other day and there were some instructions up on the wall telling the maintance men to place panel into test mode before their monthly tests. Hi ray, my legs are getting tired having to keep walking back to the panel to reset them when i'm testing them,always thought that they couldn't walk test but walked into an office the other day and there were some instructions up on the wall telling the maintance men to place panel into test mode before their monthly tests Ah, now you might like to try this. There will be a row of switches for each module, one per zone. If you flick these down, that invokes a test mode for the related zone. (It'll show FAULT condition).
Edwards Fire Alarm Systems Manual
You will need to have someone monitoring the panel as you go round, to confirm the zone did go into FIRE, and 2-way radio is always handy. Using this method will mean you don't need to go back to the 1700 after each item. I had a system that I'd modified to send signals to an in-house paging network via a set of Scotney relays, so I'd know which zones raised an alarm as I went round, but not everyone has that luxury. HTH RayB - Outgoing mail is certified Virus Free. Checked by AVG anti-virus system (Version: 6.0.543 / Virus Database: 337 - Release Date.